LogFusion Advanced Settings

Warning: These settings should generally not be used, unless you require the functionality they provide.
These can be configured in the LogFusion Settings window, by clicking the "Advanced Settings" button.

If you need any help with these advanced settings, please contact us.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableShellHooks
Type
REG_SZ
Values
0: Shell hooks will be enabled (default)
1: Shell hooks will be disabled
Versions
latest
Description
This will disable any shell hooks that the application may use. This may cause issues if the application depends on them.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\HideConfirmPrompt_ClearDeleteLog
Type
REG_SZ
Values
0: A prompt is shown when clearing and deleting the log (default)
1: No prompt is shown when clearing and deleting the log
Versions
3.1+
Description
Use this setting to hide the "Are you sure you want to clear and delete this log" prompt.

Key
HKCU\Software\Binary Fortress Software\LogFusion\HideConfirmPrompt_ClearLog
Type
REG_SZ
Values
0: A prompt is shown when clearing the log (default)
1: No prompt is shown when clearing the log
Versions
1.3+
Description
Use this setting to hide the "Are you sure you want to clear this log" prompt.

Key
HKCU\Software\Binary Fortress Software\LogFusion\HideConfirmPrompt_CloseLog
Type
REG_SZ
Values
0: A prompt is shown when closing logs (default)
1: No prompt is shown when closing logs
Versions
2.1+
Description
Use this setting to prevent LogFusion from showing the "Are you sure you want to close..." messages.

Key
HKCU\Software\Binary Fortress Software\LogFusion\FontsDefaultFamily
Type
REG_SZ
Values
Any font name, like Arial or Tahoma
Default
Auto-detect
Versions
latest
Description
Use this to override the default font family name being used in the UI. The default is usually Segoe UI.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\FontsDefaultSizePX
Type
REG_SZ
Values
5 to 50
Default
Auto-detect
Versions
latest
Description
Use this setting to force the default UI font size to a specific value.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableClearTypeForceEnabled
Type
REG_SZ
Values
0: Force using ClearType for all custom controls (default)
1: Don't use ClearType
Versions
latest
Description
Use this setting to force the application to not use ClearType.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\FontsNiceDisabled
Type
REG_SZ
Values
0: Nice fonts will be used (default)
1: Nice fonts will not be used
Versions
latest
Description
Use this setting to never use nice fonts on UI controls.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\WindowsDetectedFontNameOverride
Type
REG_SZ
Values
Any font name, like Arial or Tahoma
Default
Auto-detect
Versions
latest
Description
Use this to force the application to detect the default Windows font as something different for troubleshooting.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableBinaryFortressColumnPrompt
Type
REG_SZ
Values
0: A prompt will be show to add Binary Fortress log columns (default)
1: Binary Fortress logs will be opened without a prompt
Versions
6.8+
Description
Use this setting to automatically accept the prompt when Binary Fortress log columns are detected.

Key
HKCU\Software\Binary Fortress Software\LogFusion\BackupSettingsPath
Type
REG_SZ
Values
Path (like C:\MyBackups)
Default
Auto-detect
Versions
latest
Description
Overrides the default settings backup path.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DefaultLogEncodingOverride
Type
REG_SZ
Values
-
Default
Auto-detect
Versions
6.9.1+
Description
Use this setting to force a custom file encoding for LogFusion to use when parsing new log files, if required. A full list of available encoding values can be found in the Name column of the list here: https://docs.microsoft.com/en-us/dotnet/api/system.text.encoding?view=netframework-4.6.2#list-of-encodings.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableAdvancedWebBrowserRendering
Type
REG_SZ
Values
0: Advanced browser rendering will be enabled if needed (default)
1: Advanced browser rendering will be disabled
Versions
latest
Description
This will force the application to use the older IE web rendering, if the application needs any web rendering.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableSyncErrorMessages
Type
REG_SZ
Values
0: API syncing will show error messages when needed (default)
1: API syncing will never show an error message
Versions
latest
Description
Use this setting to force the application to never show an error if an API sync fails.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableBFAPISyncing
Type
REG_SZ
Values
0: API syncing will be enabled when needed (default)
1: API syncing will be disabled
Versions
latest
Description
This setting will cause the application to never sync with the server and will fail silently.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableCrashReportingAndTelemetry
Type
REG_SZ
Values
0: Crash reporting and telemetry will be enabled (default)
1: Crash reporting and telemetry will be disabled
Versions
latest
Description
Use this setting to disable the crash reporting and telemetry feature that allows us to collect anonymized information about crashes. This setting allows us to create better software and resolve issues more quickly and we recommend leaving it enabled.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableCrossProductScripting
Type
REG_SZ
Values
0: Cross-product scripting will be enabled if other Binary Fortress products are running (default)
1: Cross-product scripting will be disabled
Versions
latest
Description
This will force the code editor and compiler to not look for cross-product scripting assemblies.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableFreeLicenseReminderNotifications
Type
REG_SZ
Values
0: Show the free license reminder notifications every 30 days (default)
1: Don't show the free license reminder notifications
Versions
latest
Description
This setting disables the notifications you may receive every 30 days if you're using the free version.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableLoadingScreens
Type
REG_SZ
Values
0: Loading screen will be enabled (default)
1: Loading screens will be disabled
Versions
latest
Description
This setting will force any loading screens to not be shown.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableNewAssemblyResolver
Type
REG_SZ
Values
0: New assembly resolver will be enabled (default)
1: New assembly resolver will be disabled
Versions
latest
Description
Use this setting to disable the new assembly resolver. This should only be used for troubleshooting and is not recommended.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableRestoreSettingsPrompt
Type
REG_SZ
Values
0: A confirmation dialog will be shown (default)
1: No confirmation dialog will be shown
Versions
latest
Description
This will prevent the Restore Settings dialog from prompting for a confirmation.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisablePushSyncing
Type
REG_SZ
Values
0: Push Syncing will be enabled if needed (default)
1: Push Syncing will be disabled
Versions
latest
Description
This setting will force the application to never use push-syncing, if it's required by this application.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableRemoteLogAutoOpen
Type
REG_SZ
Values
0: Remote logs will be automatically re-opened (default)
1: Remote logs will not be automatically re-opened
Versions
3.1+
Description
Enabling this setting will prevent LogFusion from trying to automatically re-open logs from remote machines when it starts up.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableBackupAuto
Type
REG_SZ
Values
0: Settings will be automatically backed-up (default)
1: Settings will not be automatically backed-up
Versions
latest
Description
Use this setting to disable the settings auto-backups.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableVirtualDesktopChecks
Type
REG_SZ
Values
0: Check virtual desktops as needed (default)
1: Disable virtual desktop checks
Versions
latest
Description
Use this setting to prevent the application from seeing any virtual desktops or checking what's on them.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DontShowEncodingConfirmation
Type
REG_SZ
Values
0: Encoding confirmation dialog will be shown (default)
1: Encoding confirmation dialog will not be shown
Versions
6.9.1+
Description
This setting allows you to suppress the confirmation dialog when changing encodings.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableHotKeyBindErrorMessage
Type
REG_SZ
Values
0: An error message will be shown when a HotKey bind fails (default)
1: No error message will be shown when a HotKey bind fails
Versions
latest
Description
Use this setting to ignore hotkey bind failures.

Key
HKCU\Software\Binary Fortress Software\LogFusion\TrayIconBalloonsDisabled
Type
REG_SZ
Values
0: Tray icon notification balloons will be shown (default)
1: No tray icon notification balloons will be shown
Versions
latest
Description
Use this setting to disable tray and Growl notifications.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\MaxItemsEventLogLocal
Type
REG_SZ
Values
1 to 9999
Default
1000
Versions
3.1+
Description
Use this setting to change the number of local event log items loaded initially and the number of items loaded per update.

Key
HKCU\Software\Binary Fortress Software\LogFusion\MaxItemsEventLogRemote
Type
REG_SZ
Values
1 to 9999
Default
250
Versions
3.1+
Description
Use this setting to change the number of remote event log items loaded initially and the number of items loaded per update.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ForceAutoScrollEnabled
Type
REG_SZ
Values
0: Auto-Scroll will use the per-log setting (default)
1: Auto-Scroll will always be enabled
Versions
2.1+
Description
This setting will force LogFusion to always scroll to the bottom of log files.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableOurAppsTab
Type
REG_SZ
Values
0: The 'Our Apps' tab will be shown (default)
1: The 'Our Apps' tab will be hidden
Versions
latest
Description
Use this setting to hide the 'Our Apps' tab in the Settings window.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ForceLoadLanguageFiles
Type
REG_SZ
Values
0: Don't allow language files with errors to be loaded (default)
1: Load language files with errors and replace missing text
Versions
latest
Description
Use this setting to force the application to load invalid language files.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ShowLanguageErrors
Type
REG_SZ
Values
0: Language errors are not shown (default)
1: Language errors are shown
Versions
latest
Description
Use this setting to show language file errors. This is useful if you are a product translator.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\LineHeightPadding
Type
REG_SZ
Values
-20 to 20
Default
0
Versions
1.1.1+
Description
This setting is used to increase or decrease the line height in LogFusion. For example, use a value of 5 to make each line 5 pixels taller, or a value or -2 to make each line 2 pixels smaller.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ListViewBackgroundColourOverride
Type
REG_SZ
Values
RGB value separated by commas (ex: "255, 0, 0" for the colour red)
Default
Auto-detect
Versions
latest
Description
Overrides any listview's background colour.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ListViewForegroundColourOverride
Type
REG_SZ
Values
RGB value separated by commas (ex: "255, 0, 0" for the colour red)
Default
Auto-detect
Versions
latest
Description
Overrides any listview's foreground colour.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\LogUpdateInterval
Type
REG_SZ
Values
250 to 60000
Default
1000
Versions
2.1+
Description
This setting forces LogFusion to use a specific polling interval when updating the logs. This is useful if you have issues with logs on network computers, where you want to poll less frequently. The value is in milliseconds, so a value of 1000 is equal to 1 second.

Key
HKCU\Software\Binary Fortress Software\LogFusion\MaxEventLogLines
Type
REG_SZ
Values
1 to 2,000,000,000
Default
9999
Versions
6.9+
Description
Maximum number of event log lines to show.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\MaxLogLineLength
Type
REG_SZ
Values
-
Default
100000
Versions
6.3+
Description
This allows you to set higher or lower log line max lengths. If you run into memory issues you can try lowering the value. If your lines are being truncated you can try raising it.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\MonitorIdDetectionModeOverride
Type
REG_SZ
Values
-
Default
0
Versions
latest
Description
Use this setting to control how the monitor IDs are detected and numbered. Binary Fortress support will let you know what value to use here when troubleshooting an issue.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DebugOutputFilenameOnly
Type
REG_SZ
Values
0: The complete path is shown (default)
1: Only the filename is shown
Versions
2.1+
Description
This setting forces LogFusion to only show the filename for Debug Output logs, not the complete path.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ShowTextDebugMarking
Type
REG_SZ
Values
0: No text debug markings will be shown. (default)
1: Text debug markings will be shown.
Versions
latest
Description
Enable this setting if support is helping you troubleshoot a text rendering issue.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\TextFilterDelay
Type
REG_SZ
Values
A number between 50 and 5000
Default
250
Versions
1.2.1+
Description
This setting controls how long the text filter waits before attempting to filter the log. The default is 500ms. Set this to a higher value if you deal with large log files, and a lower value if you deal with smaller logs.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ThreadsPerIpcHandler
Type
REG_SZ
Values
0 to 100
Default
5
Versions
latest
Description
Use this setting to control the number of threads used to process IPC requests (scripting and other things). 5 is the default value, you can use a value of 0 to disable the handlers completely but this is not recommended. If you have issues when you run many scripted functions and some calls fail try increasing this value.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ToolTipLengthMax
Type
REG_SZ
Values
0 to 20000
Default
200
Versions
2.0.2+
Description
This setting controls the maximum length for tooltips. The default is 200 characters.

Key
HKCU\Software\Binary Fortress Software\LogFusion\UseLegacySelectingColour
Type
REG_SZ
Values
0: LogFusion will not use the legacy colour when selecting a row (default)
1: LogFusion will use the legacy colour when selecting a row
Versions
6.9+
Description
Use the old list selection colour.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\WebUserAgent
Type
REG_SZ
Values
A user agent string that you would like to use
Default
Auto-detect
Versions
latest
Description
Use this setting to override the user agent that gets used to internal web requests.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ViewItemLineBreak
Type
REG_SZ
Values
Any characters that you want to use to force line breaks
Default
None
Versions
3.1.5
Description
Use this setting to force line breaks into the "View Selected Rows" window. For example, if you specify , as the value LogFusion will replace , with a line break. This can make reading your logs easier.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableAllTimers
Type
REG_SZ
Values
0: All timers will function normally (default)
1: All timers will be disabled
Versions
latest
Description
Use this setting to disable all timers for troubleshooting. Enabling this setting is NOT recommended.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableInternalHungWindowDetection
Type
REG_SZ
Values
0: Hung window detection will be used (default)
1: Hung window detection will not be used
Versions
latest
Description
Use this setting to prevent the application from detecting if application windows are hung. Only enable this if customer support instructs you to.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableMonitorUpdateEvents
Type
REG_SZ
Values
0: Monitor update events will be processed normally (default)
1: Monitor update events will be ignored
Versions
latest
Description
Use this setting to force the application to ignore any monitor update events. This setting should only be used for troubleshooting, this will cause issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableInternalWMI
Type
REG_SZ
Values
0: WMI Polling will be enabled (default)
1: WMI Polling will be disabled
Versions
latest
Description
Only enable this if customer support instructs you to. It can cause performance issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableFontScaling
Type
REG_SZ
Values
0: Font Scaling will be enabled (default)
1: Font Scaling will be disabled
Versions
latest
Description
This setting can be used to force this application to never scale itself.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\FontScaleForceX
Type
REG_SZ
Values
0.25 to 5.0
Default
Auto-detect
Versions
latest
Description
Use this setting to force the application to use a specific font scaling (DPI) value.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\FontScaleForceY
Type
REG_SZ
Values
0.25 to 5.0
Default
Auto-detect
Versions
latest
Description
Use this setting to force the application to use a specific font scaling (DPI) value.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ForceOldWindowFocusMethod
Type
REG_SZ
Values
0: Use the new method to focus windows (default)
1: Use the old method to focus windows
Versions
latest
Description
Use this setting to force the application to use the older method for focusing windows.

Key
HKCU\Software\Binary Fortress Software\LogFusion\ToolTipsNotTopMost
Type
REG_SZ
Values
0: ToolTips will be allowed to be TopMost (default)
1: ToolTips will never be TopMost
Versions
latest
Description
Use this setting to troubleshoot window focus issues.

Key
HKCU\Software\Binary Fortress Software\LogFusion\LogDisableBuffer
Type
REG_SZ
Values
0: Logging will be buffered (default)
1: Logging will not be buffered
Versions
latest
Description
Only use this setting if customer support instructs you to. It can cause performance issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\LogDebugMetrics
Type
REG_SZ
Values
0: Metrics will not be logged (default)
1: Metrics will be logged
Versions
latest
Description
Only enable this if customer support instructs you to. It can cause performance issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\LogDebugStackTraces
Type
REG_SZ
Values
0: Stack Traces will not be logged (default)
1: Stack Traces will be logged
Versions
latest
Description
Only enable this if customer support instructs you to. It can cause performance issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\LogDebugThreadNames
Type
REG_SZ
Values
0: Thread Names will not be logged (default)
1: Thread Names will be logged
Versions
latest
Description
Only enable this if customer support instructs you to. It can cause performance issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\AutoTrimLogFileSizeMax
Type
REG_SZ
Values
100,000 to 999,999,999 (bytes)
Default
Auto-detect
Versions
latest
Description
Use this setting to force the application to restrict the log to a smaller size, or let it grow to a much larger size.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\MemoryTrimEnabled
Type
REG_SZ
Values
0: Memory trimming is disabled (default)
1: Memory trimming is enabled
Versions
latest
Description
Use this setting to force the application to try and trim it's memory usage. This can cause some performance issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\SendCustomDataWithCrashReports
Type
REG_SZ
Values
-
Default
Empty
Versions
latest
Description
Set this to a custom string (usually provided by our support team) so that we can track your crash reports specific to your machine to help with troubleshooting issues.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\SetWindowPosDisallowTopMost
Type
REG_SZ
Values
0: TopMost will be allowed if requested (default)
1: TopMost will never be allowed
Versions
latest
Description
This will force the application to never set anything to TopMost.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\SetWindowPosLogCalls
Type
REG_SZ
Values
0: SetWindowPos calls will not be logged (default)
1: SetWindowPos calls will be logged
Versions
latest
Description
This will force the application to log all calls to the SetWindowPos function as L2 log lines.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\DisableWebView2DetectionInstallation
Type
REG_SZ
Values
0: WebView2 will be detected and will prompt to install if needed (default)
1: No detection or installation will be done for WebView2 at startup
Versions
latest
Description
Use this setting to disable the WebView2 detection at startup that prompts to install the WebView2 runtime.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\WebView2DisableGpu
Type
REG_SZ
Values
0: GPU rendering will be enabled (default)
1: GPU rendering will be disabled
Versions
latest
Description
Use this setting to disable GPU rendering in the WebView2 control.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\WebView2DisableSoftwareRasterizer
Type
REG_SZ
Values
0: Software rasterizer will be enabled. (default)
1: Software rasterizer will be disabled.
Versions
latest
Description
Use this setting to disable the software rasterizer for the WebView2 control.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\WebView2EnableLogging
Type
REG_SZ
Values
0: Logging will not be enabled for WebView2 controls (default)
1: Logging will be enabled for WebView2 controls
Versions
latest
Description
This will enable logging for the WebView2 controls.
WARNING: This will make a console window appear for each window! You can just ignore those while collecting the log data.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\WebView2ForceNoCommandLine
Type
REG_SZ
Values
0: The command line will be used as needed (default)
1: No command line options will be used
Versions
latest
Description
This forces the WebView2 control to be created with no extra command line options. Use this only for troubleshooting. This takes priority over any other WebView2 settings.
LogFusion must be restarted for this setting to take effect.

Key
HKCU\Software\Binary Fortress Software\LogFusion\WebView2CommandLineOverride
Type
REG_SZ
Values
-
Default
Auto-detect
Versions
latest
Description
Use this setting to override the flags passed to the underlying WebView2 control. This is not recommended and should only be used for troubleshooting. Set this to a value of - to use a blank value as the override.
LogFusion must be restarted for this setting to take effect.